Calculate allowable length of the corroded area in the pipe.
Arguments
- dep
design pressure of pipe, [PSI]. Type:
assert_double
.- maop
maximum allowable operating pressure - MAOP, [PSI]. Type:
assert_double
.- d
nominal outside diameter of pipe, [inch]. Type:
assert_double
.- wth
nominal wall thickness of pipe, [inch]. Type:
assert_double
.- depth
measured maximum depth of the corroded area, [inch]. Type:
assert_double
.- l
measured maximum longitudinal length of the corroded area, [inch]. Type:
assert_double
.
Value
Allowable length of the corroded area in the pipe, [inch].
Type: assert_double
.
References
ASME B31G-1991. Manual for determining the remaining strength of corroded pipelines. A supplement to ASTME B31 code for pressure piping.
Examples
library(pipenostics)
# Corrosion is low, no limit for the corroded area length:
b31gacl(1093, 910, 30, .438, .1, 7.5)
#> [1] Inf
# Finite allowed length of the corroded area
b31gacl(438, 400, 20, .25, .18, 10)
#> [1] 2.018